  1. Class 1 Div 2 Enclosures - Mike Holt's Forum

    Jul 24, 2009 · Can someone refer me to where the code may list acceptable enclosures for Class 1 Div 2 that will be used for pulling and possibly splicing of branch circuits (any arcing device …

  2. NEMA rating for Enclosures | Information by Electrical …

    Oct 29, 2019 · But to specifically answer your question, NEMA type 7 is (was) for Class I, Division 1, Groups A, B, C, or D. You can use a NEMA 7 enclosure for Class 1 Division 2 if you like, …

  3. Choosing the Right Enclosure - NEMA 4x versus NEMA 4x Class 1 …

    Jan 26, 2014 · One is specifically rated NEMA 4X Class 1 Division while the other is just NEMA 4x. My system is going to be used in a Class 1 Division II environment and all the electrical …

  4. Control Panel in Class 1 Division 2 area - Mike Holt's Forum

    May 7, 2009 · The area will now get a Class 1 Division 2 hazardous area classification as new product will be made there. Does tha pane need to be explotion proof or is it sufficient to add …

  5. Class 1 Division 2 NEMA Ratings | Information by Electrical ...

    Jan 30, 2019 · We are having a difference of opinion with an engineering firm concerning NEMA Ratings of equipment in Class 1 Division 2 areas. In section 501.105 what NEMA ratings are …

  6. Conduit and Seals for Explosion Proof Enclosures in Class I Div 2 …

    Aug 1, 2024 · But a measuring device such as pressure transmitter that is listed as explosionproof would also be such an enclosure, right? So when running conduit in a Class I Div 2 area to …

  7. Fittings in a class 1 div 2 area | Information by Electrical ...

    Feb 25, 2025 · Don't have my code book with me right now but my understanding is in class 1 div 2 fittings only need to be explosion proof when required by the code. For example coming out …

  8. NEMA Enclosure Requirements for Class II Division II Area

    Feb 18, 2020 · The general requirements for boxes and fittings in Class II, Division 2 is in Section 502.10 (B) (4). For specific equipment enclosures, the evaluator should cite specific NEC …

  9. Class I Divison 2 Enclosure Allowance | Information by Electrical ...

    Mar 21, 2018 · Is ANY NEMA 4/4X enclosure acceptable for Class I Div 2 when you don't need to go explosion proof? It seems that 500.8 (A) requires some kind of listing or labeling and Rittal …

  10. Class II, Div 1 Requirement for equipment - Mike Holt's Forum

    Nov 6, 2014 · If that is the case, then I read this as saying that the enclosure we use for Class II, Div 1, must be rated as such or in other words, for Class II, Div 1, we'll need to use explosion …